• JL-04 Load cell for bench  scale
    JL-04 Load cell for bench scale
    JL-04 Load cell for bench  scale  Model JL-04 Model JL-04 Rated Capacities 60,100, 200,350, 500,800(kg) Output Impedance 350±5 Ω Rated Output 2.0 mV/V±5% Insulation Impedance ≥5000 MΩ/50VDC Non-linearity 0.02 %F.S Safe Overload 150 % F.S Hysteresis 0.02 % F.S Ultimate Overload 200 % F.S Repeatability 0.02 % F.S Operating Temperature Range -20~60 ℃ Creep(20min) 0.02 % F.S Recommended Excitation 5~12 VDC Temperature Effect On Output 0.002 % F.S /℃ Maximum Excitation 15 VDC Temperature  Effect On Zero 0.003 % F.S /℃ Construction Aluminum Alloy Zero Balance ±0.0200 mV/V Protection Class IP66 / IP67 Input Impedance 410±15 Ω Cable φ5×2 m Mode of Connection Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-)
  • JL-03 Load cell
    JL-03 Load cell for bench scale
    JL-03 Load cell for bench  scale
  • NA2 Load cell
    JADEVER JL-02 Load cell for bench scale
    JL-02 Load cell for bench  scale  Model JL-02 Model JL-02 Rated Capacities 60/100/150/200/250/300/350/500(kg) Output Impedance 350±5 Ω Rated Output 2.0 mV/V±5% Insulation Impedance ≥5000 MΩ Non-linearity 0.02 %F.S Safe Overload 150 %F.S Hysteresis 0.02 %F.S Ultimate Overload 200 %F.S Repeatability 0.02 %F.S Operating Temperature Range -20~60 ℃ Creep(20min) 0.02 %F.S Recommended Excitation 5~12 VDC Temperature Effect On Output 0.002 %F.S/℃ Maximum Excitation 15 VDC Temperature  Effect On Zero 0.003 %F.S/℃ Construction Aluminum Alloy Zero Balance ±0.0200 mV/V Protection Class IP67 / IP68 Input Impedance 410±15 Ω Cable φ5×15 cm Mode of Connection Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-)
  • JWP waterproof Load cell
    JWP waterproof Load cell
    Main technical data Rated load kg 3/5/10/20/40 Accuracy class C3 Maxinum number of load cell verification intervals nmax nmax Minimum load cell verification intervals Vmin Vmin Combined error %FS %FS Creep  %FS/30min %FS/30min Temp. effect on sensitivity %FS/10℃ %FS/10℃ Temp. effect on zero output %FS/10℃ %FS/10℃ Sensitivity  mv/v 2.0±0.2 Input resistance  Ω 406±6 Output resistance Ω 350±3 Insulation resistance MΩ ≥5000(50VDC) Zero output %FS ≤±2 Compensated temperature range ℃ -10~40 Operating temperature range ℃ -35~65 Recommended excitation voltage V 5~12(DC) Maximum excitation voltage V 16(DC) Safe over load  %FS 150 Ultimate over load %FS 300 Four comer error  0.02% load value Maximum table size mm 250×250
  • JL-01 Load cell for table top scale
    JL-01 Load cell for table top scale
    JL-01 Load cell for table top scale  Model JL-01 Model JL-01 Rated Capacities(kg) 3,5,6,7.5,10,12,15,20,30,35,40 Output Impedance 350±5 Ω Rated Output 2.0 mV/V±10% Insulation Impedance ≥5000 MΩ Non-linearity 0.02 %F.S Safe Overload 150 %F.S Hysteresis 0.02 %F.S Ultimate Overload 200 %F.S Repeatability 0.02 %F.S Operating Temperature Range -20~60℃ Creep(20min)/DR 0.02 %F.S Recommended Excitation 5~12 VDC Temperature Effect On Output 0.002 %F.S/℃ Maximum Excitation 15 VDC Temperature  Effect On Zero 0.003 %F.S/℃ Construction Aluminum Alloy Zero Balance ±0.0200 mV/V Protection Class IP67 / IP68 Input Impedance 410±15 Ω Cable φ4×45 cm Mode of Connection Red(EXC+),Black(EXC-),Green(SIG+),White(SIG-)
  • godex label printer
    GODEX EZ1100Plus Desktop Thermal Transfer Printer
    GODEX EZ1100Plus Desktop Thermal Transfer Printer is used for medium duty application.